TagSiteAreaEquipmentExZoneGasTLast inspectedGradeResultNext due
KUR-CS-132 Kurra Camp — switchroom & fuel farm Bowser island Control station Ex de Zone 1 IIC T4 — — Not inspected —
KUR-CS-160 Kurra Camp — switchroom & fuel farm Bowser island Control station Ex de Zone 1 IIB T6 — — Not inspected —
KUR-GD-147 Kurra Camp — switchroom & fuel farm Bowser island Gas detector Ex d Zone 1 IIA T3 — — Not inspected —
KUR-HT-129 Kurra Camp — switchroom & fuel farm Bowser island Heater Ex e Zone 1 IIC T4 — — Not inspected —
KUR-LT-109 Kurra Camp — switchroom & fuel farm Bowser island Light fitting Ex d Zone 1 IIC T4 18 Sep 2026 Detailed Pass In date
KUR-LT-133 Kurra Camp — switchroom & fuel farm Bowser island Light fitting Ex d Zone 1 IIA T4 — — Not inspected —
KUR-SV-126 Kurra Camp — switchroom & fuel farm Bowser island Solenoid valve Ex ia Zone 1 IIA T3 23 Sep 2026 Detailed Pass In date
KUR-CG-142 Kurra Camp — switchroom & fuel farm Fuel farm Cable gland set Ex e Zone 1 IIA T4 — — Not inspected —
KUR-CG-151 Kurra Camp — switchroom & fuel farm Fuel farm Cable gland set Ex e Zone 1 IIC T6 — — Not inspected —
KUR-CG-164 Kurra Camp — switchroom & fuel farm Fuel farm Cable gland set Ex e Zone 1 IIC T4 — — Not inspected —
KUR-HT-108 Kurra Camp — switchroom & fuel farm Fuel farm Heater Ex e Zone 1 IIC T4 17 Sep 2026 Detailed Pass In date
KUR-JB-158 Kurra Camp — switchroom & fuel farm Fuel farm Junction box Ex e Zone 1 IIC T6 — — Not inspected —
KUR-SO-102 Kurra Camp — switchroom & fuel farm Fuel farm Socket outlet Ex de Zone 1 IIC T6 15 Sep 2026 Detailed Pass In date
KUR-SO-149 Kurra Camp — switchroom & fuel farm Fuel farm Socket outlet Ex de Zone 1 IIA T4 — — Not inspected —
KUR-SV-112 Kurra Camp — switchroom & fuel farm Fuel farm Solenoid valve Ex ia Zone 1 IIA T6 19 Sep 2026 Detailed Pass In date
KUR-CG-140 Kurra Camp — switchroom & fuel farm Generator yard Cable gland set Ex e Zone 2 IIB T3 — — Not inspected —
KUR-CS-137 Kurra Camp — switchroom & fuel farm Generator yard Control station Ex de Zone 1 IIB T4 — — Not inspected —
KUR-GD-122 Kurra Camp — switchroom & fuel farm Generator yard Gas detector Ex d Zone 1 IIA T3 22 Sep 2026 Detailed Pass In date
KUR-HT-156 Kurra Camp — switchroom & fuel farm Generator yard Heater Ex e Zone 2 IIC T6 — — Not inspected —
KUR-JB-105 Kurra Camp — switchroom & fuel farm Generator yard Junction box Ex e Zone 1 IIB T4 16 Sep 2026 Detailed Pass In date
KUR-LT-120 Kurra Camp — switchroom & fuel farm Generator yard Level transmitter Ex ia Zone 2 IIC T6 21 Sep 2026 Detailed Pass In date
KUR-SV-117 Kurra Camp — switchroom & fuel farm Generator yard Solenoid valve Ex ia Zone 2 IIC T6 20 Sep 2026 Detailed Pass In date