BP10-0008 · Scheduled service
Quarterly service — BP10-0008
08 Jul 2026 08:30 · 2 h booked · last serviced 08 Jul 2026
Princess Road, Balga WA 6061
Access: Unit sits beside the outdoor pool concourse. Service before 6 am or after 8 pm, or close the zone.
Sauna
✓ Heater elements tested — resistance within spec
✓ Stones inspected, re-stacked, crumbled stones replaced
✓ Controller & temperature sensor tested
✓ Sauna temperature reached °C
✓ Time to temperature min
✓ Benches cleaned, sanded where needed and oiled
✓ Door glass, hinges and seal inspected
✓ Vent valve operating
Electrical & safety
✓ RCD trip test ms
✓ Isolator, inlet and leads inspected
✓ Lighting & emergency stop working
✓ Safe-use signage present & legible
Exterior
✓ Container, deck & steps inspected
✓ Before & after photos taken
Photos
Before & after photos go here.
Parts used
OIL-BNCH Bench oil / paraffin finish 1 L1 btl
CLN-SAN Sauna cleaner / sanitiser 5 L1 ea
Time
Liam Hartley · On site2 h