Blackout Performance

Job SJ-26-0448

Technician app — Kade Morrison
Demo 09 Oct 2026
BP10-0005 · Scheduled service
Ridgeline Village — Newman
14 / 14
Quarterly service — BP10-0005
04 Jun 2026 07:00 · 2 h booked · last serviced 04 Sep 2026
Great Northern Hwy, Newman WA 6753
Access: Report to village reception. Escort required past the wet mess. Induction required.
Sauna
✓ Heater elements tested — resistance within spec
✓ Stones inspected, re-stacked, crumbled stones replaced
✓ Controller & temperature sensor tested
✓ Sauna temperature reached °C
✓ Time to temperature min
✓ Benches cleaned, sanded where needed and oiled
✓ Door glass, hinges and seal inspected
✓ Vent valve operating
Electrical & safety
✓ RCD trip test ms
✓ Isolator, inlet and leads inspected
✓ Lighting & emergency stop working
✓ Safe-use signage present & legible
Exterior
✓ Container, deck & steps inspected
✓ Before & after photos taken
Photos
After service — benches oiled
After service — benches oiled
Parts used
OIL-BNCH Bench oil / paraffin finish 1 L1 btl
CLN-SAN Sauna cleaner / sanitiser 5 L1 ea
Time
Kade Morrison · Travel1.5 h
Kade Morrison · On site2 h
✓ Signed off 04 Jun 2026 · 14:20
Signed by Dean Kowalski