BP10-0003 · Scheduled service
6-monthly service — BP10-0003
06 Apr 2026 10:00 · 2 h booked · last serviced 02 Oct 2026
4/71 Howe Street, Osborne Park WA 6017
Access: Rear roller door.
Sauna
✓ Heater elements tested — resistance within spec
✓ Stones inspected, re-stacked, crumbled stones replaced
✓ Controller & temperature sensor tested
✓ Sauna temperature reached °C
✓ Time to temperature min
✓ Benches cleaned, sanded where needed and oiled
✓ Door glass, hinges and seal inspected
✓ Vent valve operating
Electrical & safety
✓ RCD trip test ms
✓ Isolator, inlet and leads inspected
✓ Lighting & emergency stop working
✓ Safe-use signage present & legible
Exterior
✓ Container, deck & steps inspected
✓ Before & after photos taken
Photos

Parts used
OIL-BNCH Bench oil / paraffin finish 1 L1 btl
CLN-SAN Sauna cleaner / sanitiser 5 L1 ea
Time
Liam Hartley · On site2 h