Blackout Performance

SJ-26-0481

Quarterly service — BP20-0009 — Westline Civil Contractors
Demo 09 Oct 2026
To scheduleScheduledIn progressCompleteInvoiced Scheduled service
Checklist19 / 19
Sauna
✓Heater elements tested — resistance within spec
✓Stones inspected, re-stacked, crumbled stones replaced
✓Controller & temperature sensor tested
✓Sauna temperature reached87 °C
✓Time to temperature32 min
✓Benches cleaned, sanded where needed and oiled
✓Door glass, hinges and seal inspected
✓Vent valve operating
Ice room
✓Ice room temperature reached-10 °C
✓Condensing unit coils cleaned
✓Evaporator fan & condensate drain checked
✓Door gasket & heater strip checked
✓Return-air filter replaced
Electrical & safety
✓RCD trip test22 ms
✓Isolator, inlet and leads inspected
✓Lighting & emergency stop working
✓Safe-use signage present & legible
Exterior
✓Container, deck & steps inspected
✓Before & after photos taken
Photos
After service — benches oiled
After service — benches oiled
Partsallocated now, issued from stock on sign-off
PartQty
OIL-BNCH — Bench oil / paraffin finish 1 L 1 btl Issued
CLN-SAN — Sauna cleaner / sanitiser 5 L 1 ea Issued
FLT-AIR — Ice room return-air filter 1 ea Issued
Timesheet9.5 h
DateWhoTypeHoursNote
02 Jul 2026 Liam Hartley Travel 6.5 —
02 Jul 2026 Liam Hartley On site 3 —
Customer
Westline Civil Contractors
Site
Kalgoorlie Workers Village
Great Eastern Hwy, Kalgoorlie WA 6430
Unit
BP20-0009
Technician
Liam Hartley
Scheduled
02 Jul 2026 · 07:00 · 3 h
Charging
Covered by lease
Site access: Reception 24 h.
Sign-off
Completed 02 Jul 2026 · 15:05 · signed by Brendan Shaw
✓ 3 part line(s) issued from stock ✓ BP20-0009 next service 03 Oct 2026 ✓ Covered by lease — no charge