To scheduleScheduledIn progressCompleteInvoiced Scheduled service
Checklist14 / 14
Sauna
✓Heater elements tested — resistance within spec
✓Stones inspected, re-stacked, crumbled stones replaced
✓Controller & temperature sensor tested
✓Sauna temperature reached85 °C
✓Time to temperature28 min
✓Benches cleaned, sanded where needed and oiled
✓Door glass, hinges and seal inspected
✓Vent valve operating
Electrical & safety
✓RCD trip test17 ms
✓Isolator, inlet and leads inspected
✓Lighting & emergency stop working
✓Safe-use signage present & legible
Exterior
✓Container, deck & steps inspected
✓Before & after photos taken
Photos
No photos yet.
Partsallocated now, issued from stock on sign-off
| Part | Qty | |||
|---|---|---|---|---|
| OIL-BNCH — Bench oil / paraffin finish 1 L | 1 | btl | Issued | |
| CLN-SAN — Sauna cleaner / sanitiser 5 L | 1 | ea | Issued | |
Timesheet2 h
| Date | Who | Type | Hours | Note | |
|---|---|---|---|---|---|
| 21 Apr 2026 | Liam Hartley | On site | 2 | — | |
- Customer
- Coastal Leisure WA
- Site
- Rockingham AquaticElanora Drive, Rockingham WA 6168
- Unit
- BP10-0010
- Technician
- Liam Hartley
- Scheduled
- 21 Apr 2026 · 07:00 · 2 h
- Charging
- Covered by lease
Sign-off
Completed 21 Apr 2026 · 14:20 · signed by Gemma Rossi
✓ 2 part line(s) issued from stock ✓ BP10-0010 next service 21 Oct 2026 ✓ Covered by lease — no charge